Network Working Group                                         C. Lonvick
Request for Comments: 3164                                 Cisco Systems
Category: Informational                                      August 2001


                        The BSD syslog Protocol

Status of this Memo

   This memo provides information for the Internet community.  It does
   not specify an Internet standard of any kind.  Distribution of this
   memo is unlimited.

Copyright Notice

   Copyright (C) The Internet Society (2001).  All Rights Reserved.

Abstract

   This document describes the observed behavior of the syslog protocol.
   This protocol has been used for the transmission of event
   notification messages across networks for many years.  While this
   protocol was originally developed on the University of California
   Berkeley Software Distribution (BSD) TCP/IP system implementations,
   its value to operations and management has led it to be ported to
   many other operating systems as well as being embedded into many
   other networked devices.

Table of Contents

   1. Introduction....................................................2
   1.1 Events and Generated Messages..................................3
   1.2 Operations of the Message Receivers............................5
   2. Transport Layer Protocol........................................5
   3. Definitions and Architecture....................................5
   4. Packet Format and Contents......................................7
   4.1 syslog Message Parts...........................................8
   4.1.1 PRI Part.....................................................8
   4.1.2 HEADER Part of a syslog Packet..............................10
   4.1.3 MSG Part of a syslog Packet.................................11
   4.2 Original syslog Packets Generated by a Device.................12
   4.3 Relayed syslog Packets........................................12
   4.3.1 Valid PRI and TIMESTAMP.....................................13
   4.3.2 Valid PRI but no TIMESTAMP or invalid TIMESTAMP.............13
   4.3.3 No PRI or Unidentifiable PRI................................14
   5. Conventions....................................................14
   5.1 Dates and Times...............................................15
   5.2 Domain Name and Address.......................................15



Lonvick                      Informational                      [Page 1]


RFC 3164                The BSD syslog Protocol              August 2001


   5.3 Originating Process Information...............................15
   5.4 Examples......................................................16
   6. Security Considerations........................................18
   6.1 Packet Parameters.............................................19
   6.2 Message Authenticity..........................................19
   6.2.1 Authentication Problems.....................................19
   6.2.2 Message Forgery.............................................20
   6.3 Sequenced Delivery............................................20
   6.3.1 Single Source to a Destination..............................20
   6.3.2 Multiple Sources to a Destination...........................21
   6.3.3 Multiple Sources to Multiple Destinations...................21
   6.3.4 Replaying...................................................22
   6.4 Reliable Delivery.............................................22
   6.5 Message Integrity.............................................22
   6.6 Message Observation...........................................22
   6.7 Message Prioritization and Differentiation....................23
   6.8 Misconfiguration..............................................24
   6.9 Forwarding Loop...............................................24
   6.10 Load Considerations..........................................25
   7. IANA Considerations............................................25
   8. Conclusion and Other Efforts...................................25
   Acknowledgements..................................................26
   References........................................................27
   Author's Address..................................................28
   Full Copyright Statement..........................................29

1. Introduction

   Since the beginning, life has relied upon the transmission of
   messages.  For the self-aware organic unit, these messages can relay
   many different things.  The messages may signal danger, the presence
   of food or the other necessities of life, and many other things.  In
   many cases, these messages are informative to other units and require
   no acknowledgement.  As people interacted and created processes, this
   same principle was applied to societal communications.  As an
   example, severe weather warnings may be delivered through any number
   of channels - a siren blowing, warnings delivered over television and
   radio stations, and even through the use of flags on ships.  The
   expectation is that people hearing or seeing these warnings would
   realize their significance and take appropriate action.  In most
   cases, no responding acknowledgement of receipt of the warning is
   required or even desired.  Along these same lines, operating systems,
   processes and applications were written to send messages of their own
   status, or messages to indicate that certain events had occurred.
   These event messages generally had local significance to the machine
   operators.  As the operating systems, processes and applications grew
   ever more complex, systems were devised to categorize and log these
   diverse messages and allow the operations staff to more quickly



Lonvick                      Informational                      [Page 2]


RFC 3164                The BSD syslog Protocol              August 2001


   differentiate the notifications of problems from simple status
   messages.  The syslog process was one such system that has been
   widely accepted in many operating systems.  Flexibility was designed
   into this process so the operations staff have the ability to
   configure the destination of messages sent from the processes running
   on the device.  In one dimension, the events that were received by
   the syslog process could be logged to different files and also
   displayed on the console of the device.  In another dimension, the
   syslog process could be configured to forward the messages across a
   network to the syslog process on another machine. The syslog process
   had to be built network-aware for some modicum of scalability since
   it was known that the operators of multiple systems would not have
   the time to access each system to review the messages logged there.
   The syslog process running on the remote devices could therefore be
   configured to either add the message to a file, or to subsequently
   forward it to another machine.

   In its most simplistic terms, the syslog protocol provides a
   transport to allow a machine to send event notification messages
   across IP networks to event message collectors - also known as syslog
   servers.  Since each process, application and operating system was
   written somewhat independently, there is little uniformity to the
   content of syslog messages.  For this reason, no assumption is made
   upon the formatting or contents of the messages.  The protocol is
   simply designed to transport these event messages.  In all cases,
   there is one device that originates the message.  The syslog process
   on that machine may send the message to a collector.  No
   acknowledgement of the receipt is made.

   One of the fundamental tenets of the syslog protocol and process is
   its simplicity.  No stringent coordination is required between the
   transmitters and the receivers.  Indeed, the transmission of syslog
   messages may be started on a device without a receiver being
   configured, or even actually physically present.  Conversely, many
   devices will most likely be able to receive messages without explicit
   configuration or definitions.  This simplicity has greatly aided the
   acceptance and deployment of syslog.

1.1 Events and Generated Messages

   The writers of the operating systems, processes and applications have
   had total control over the circumstances that would generate any
   message.  In some cases, messages are generated to give status. These
   can be either at a certain period of time, or at some other interval
   such as the invocation or exit of a program.  In other cases, the
   messages may be generated due to a set of conditions being met.  In
   those cases, either a status message or a message containing an alarm
   of some type may be generated.  It was considered that the writers of



Lonvick                      Informational                      [Page 3]


RFC 3164                The BSD syslog Protocol              August 2001


   the operating systems, processes and applications would quantify
   their messages into one of several broad categories.  These broad
   categories generally consist of the facility that generated them,
   along with an indication of the severity of the message.  This was so
   that the operations staff could selectively filter the messages and
   be presented with the more important and time sensitive notifications
   quickly, while also having the ability to place status or informative
   messages in a file for later perusal.   Other options for displaying
   or storing messages have been seen to exist as well.

   Devices MUST be configured with rules for displaying and/or
   forwarding the event messages.  The rules that have been seen are
   generally very flexible.  An administrator may want to have all
   messages stored locally as well as to have all messages of a high
   severity forwarded to another device.  They may find it appropriate
   to also have messages from a particular facility sent to some or all
   of the users of the device and displayed on the system console.
   However the administrator decides to configure the disposition of the
   event messages, the process of having them sent to a syslog collector
   generally consists of deciding which facility messages and which
   severity levels will be forwarded, and then defining the remote
   receiver.  For example, an administrator may want all messages that
   are generated by the mail facility to be forwarded to one particular
   event message collector.  Then the administrator may want to have all
   kernel generated messages sent to a different syslog receiver while,
   at the same time, having the critically severe messages from the
   kernel also sent to a third receiver.  It may also be appropriate to
   have those messages displayed on the system console as well as being
   mailed to some appropriate people, while at the same time, being sent
   to a file on the local disk of the device.  Conversely, it may be
   appropriate to have messages from a locally defined process only
   displayed on the console but not saved or forwarded from the device.
   In any event, the rules for this will have to be generated on the
   device.  Since the administrators will then know which types of
   messages will be received on the collectors, they should then make
   appropriate rules on those syslog servers as well.

   The contents of a message have also been at the discretion of its
   creator.  It has been considered to be good form to write the
   messages so that they are informative to the person who may be
   reading them.  It has also been considered good practice to include a
   timestamp and some indication of the sending device and the process
   that originated it in the messages.  However, none of those are
   stringently required.

   It should be assumed that any process on any device might generate an
   event message.  This may include processes on machines that do not
   have any local storage - e.g., printers, routers, hubs, switches, and



Lonvick                      Informational                      [Page 4]


RFC 3164                The BSD syslog Protocol              August 2001


   diskless workstations.  In that case, it may be imperative that event
   messages are transported to a collector so that they may be recorded
   and hopefully viewed by an operator.

1.2 Operations of the Message Receivers

   It is beyond the scope of this document to specify how event messages
   should be processed when they are received.  Like the operations
   described in Section 1.1, they generally may be displayed to the
   appropriate people, saved onto disk, further forwarded, or any
   combination of these.  The rules for determining the disposition of
   received messages have been seen to be identical to the rules for
   determining the disposition of locally generated messages.

   As a very general rule, there are usually many devices sending
   messages to relatively fewer collectors.  This fan-in process allows
   an administrator to aggregate messages into relatively few
   repositories.

2. Transport Layer Protocol

   syslog uses the user datagram protocol (UDP) [1] as its underlying
   transport layer mechanism.  The UDP port that has been assigned to
   syslog is 514.  It is RECOMMENDED that the source port also be 514 to
   indicate that the message is from the syslog process of the sender,
   but there have been cases seen where valid syslog messages have come
   from a sender with a source port other than 514.  If the sender uses
   a source port other than 514 then it is RECOMMENDED and has been
   considered to be good form that subsequent messages are from a single
   consistent port.

3. Definitions and Architecture

   The following definitions will be used in this document.

         A machine that can generate a message will be called a
         "device".

         A machine that can receive the message and forward it to
         another machine will be called a "relay".

         A machine that receives the message and does not relay it to
         any other machines will be called a "collector".  This has been
         commonly known as a "syslog server".

         Any device or relay will be known as the "sender" when it sends
         a message.




Lonvick                      Informational                      [Page 5]


RFC 3164                The BSD syslog Protocol              August 2001


         Any relay or collector will be known as the "receiver" when it
         receives the message.

   The architecture of the devices may be summarized as follows:

         Senders send messages to relays or collectors with no knowledge
         of whether it is a collector or relay.

         Senders may be configured to send the same message to multiple
         receivers.

         Relays may send all or some of the messages that they receive
         to a subsequent relay or collector.  In the case where they do
         not forward all of their messages, they are acting as both a
         collector and a relay.  In the following diagram, these devices
         will be designated as relays.

         Relays may also generate their own messages and send them on to
         subsequent relays or collectors.  In that case it is acting as
         a device.  These devices will also be designated as a relay in
         the following diagram.

   The following architectures shown in Diagram 1 are valid while the
   first one has been known to be the most prevalent.  Other
   arrangements of these examples are also acceptable.  As noted above,
   in the following diagram relays may pass along all or some of the
   messages that they receive along with passing along messages that
   they internally generate.























Lonvick                      Informational                      [Page 6]


RFC 3164                The BSD syslog Protocol              August 2001


         +------+         +---------+
         |Device|---->----|Collector|
         +------+         +---------+

         +------+         +-----+         +---------+
         |Device|---->----|Relay|---->----|Collector|
         +------+         +-----+         +---------+

         +------+     +-----+            +-----+     +---------+
         |Device|-->--|Relay|-->--..-->--|Relay|-->--|Collector|
         +------+     +-----+            +-----+     +---------+

         +------+         +-----+         +---------+
         |Device|---->----|Relay|---->----|Collector|
         |      |-\       +-----+         +---------+
         +------+  \
                    \      +-----+         +---------+
                     \-->--|Relay|---->----|Collector|
                           +-----+         +---------+

         +------+         +---------+
         |Device|---->----|Collector|
         |      |-\       +---------+
         +------+  \
                    \      +-----+         +---------+
                     \-->--|Relay|---->----|Collector|
                           +-----+         +---------+

         +------+         +-----+            +---------+
         |Device|---->----|Relay|---->-------|Collector|
         |      |-\       +-----+         /--|         |
         +------+  \                     /   +---------+
                    \      +-----+      /
                     \-->--|Relay|-->--/
                           +-----+

           Diagram 1.  Some Possible syslog Architectures

4. Packet Format and Contents

   The payload of any IP packet that has a UDP destination port of 514
   MUST be treated as a syslog message.  There MAY be differences
   between the format of an originally transmitted syslog message and
   the format of a relayed message.  In essence, it is RECOMMENDED to
   transmit a syslog message in the format specified in this document,
   but it is not required.  If a relay is able to recognize the message
   as adhering to that format then it MUST retransmit the message
   without making any changes to it.  However, if a relay receives a



Lonvick                      Informational                      [Page 7]


RFC 3164                The BSD syslog Protocol              August 2001


   message but cannot discern the proper implementation of the format,
   it is REQUIRED to modify the message so that it conforms to that
   format before it retransmits it.  Section 4.1 will describe the
   RECOMMENDED format for syslog messages.  Section 4.2 will describe
   the requirements for originally transmitted messages and Section 4.3
   will describe the requirements for relayed messages.

4.1 syslog Message Parts

   The full format of a syslog message seen on the wire has three
   discernable parts.  The first part is called the PRI, the second part
   is the HEADER, and the third part is the MSG.  The total length of
   the packet MUST be 1024 bytes or less.  There is no minimum length of
   the syslog message although sending a syslog packet with no contents
   is worthless and SHOULD NOT be transmitted.

4.1.1 PRI Part

   The PRI part MUST have three, four, or five characters and will be
   bound with angle brackets as the first and last characters.  The PRI
   part starts with a leading "<" ('less-than' character), followed by a
   number, which is followed by a ">" ('greater-than' character). The
   code set used in this part MUST be seven-bit ASCII in an eight-bit
   field as described in RFC 2234 [2].  These are the ASCII codes as
   defined in "USA Standard Code for Information Interchange" [3].  In
   this, the "<" character is defined as the Augmented Backus-Naur Form
   (ABNF) %d60, and the ">" character has ABNF value %d62.  The number
   contained within these angle brackets is known as the Priority value
   and represents both the Facility and Severity as described below.
   The Priority value consists of one, two, or three decimal integers
   (ABNF DIGITS) using values of %d48 (for "0") through %d57 (for "9").

   The Facilities and Severities of the messages are numerically coded
   with decimal values.  Some of the operating system daemons and
   processes have been assigned Facility values.  Processes and daemons
   that have not been explicitly assigned a Facility may use any of the
   "local use" facilities or they may use the "user-level" Facility.
   Those Facilities that have been designated are shown in the following
   table along with their numerical code values.

       Numerical             Facility
          Code

           0             kernel messages
           1             user-level messages
           2             mail system
           3             system daemons
           4             security/authorization messages (note 1)



Lonvick                      Informational                      [Page 8]


RFC 3164                The BSD syslog Protocol              August 2001


           5             messages generated internally by syslogd
           6             line printer subsystem
           7             network news subsystem
           8             UUCP subsystem
           9             clock daemon (note 2)
          10             security/authorization messages (note 1)
          11             FTP daemon
          12             NTP subsystem
          13             log audit (note 1)
          14             log alert (note 1)
          15             clock daemon (note 2)
          16             local use 0  (local0)
          17             local use 1  (local1)
          18             local use 2  (local2)
          19             local use 3  (local3)
          20             local use 4  (local4)
          21             local use 5  (local5)
          22             local use 6  (local6)
          23             local use 7  (local7)

           Table 1.  syslog Message Facilities

        Note 1 - Various operating systems have been found to utilize
           Facilities 4, 10, 13 and 14 for security/authorization,
           audit, and alert messages which seem to be similar.
        Note 2 - Various operating systems have been found to utilize
           both Facilities 9 and 15 for clock (cron/at) messages.

   Each message Priority also has a decimal Severity level indicator.
   These are described in the following table along with their numerical
   values.

        Numerical         Severity
          Code

           0       Emergency: system is unusable
           1       Alert: action must be taken immediately
           2       Critical: critical conditions
           3       Error: error conditions
           4       Warning: warning conditions
           5       Notice: normal but significant condition
           6       Informational: informational messages
           7       Debug: debug-level messages

           Table 2. syslog Message Severities






Lonvick                      Informational                      [Page 9]


RFC 3164                The BSD syslog Protocol              August 2001


   The Priority value is calculated by first multiplying the Facility
   number by 8 and then adding the numerical value of the Severity. For
   example, a kernel message (Facility=0) with a Severity of Emergency
   (Severity=0) would have a Priority value of 0.  Also, a "local use 4"
   message (Facility=20) with a Severity of Notice (Severity=5) would
   have a Priority value of 165.  In the PRI part of a syslog message,
   these values would be placed between the angle brackets as <0> and
   <165> respectively.  The only time a value of "0" will follow the "<"
   is for the Priority value of "0". Otherwise, leading "0"s MUST NOT be
   used.

4.1.2 HEADER Part of a syslog Packet

   The HEADER part contains a timestamp and an indication of the
   hostname or IP address of the device.  The HEADER part of the syslog
   packet MUST contain visible (printing) characters.  The code set used
   MUST also be seven-bit ASCII in an eight-bit field like that used in
   the PRI part.  In this code set, the only allowable characters are
   the ABNF VCHAR values (%d33-126) and spaces (SP value %d32).

   The HEADER contains two fields called the TIMESTAMP and the HOSTNAME.
   The TIMESTAMP will immediately follow the trailing ">" from the PRI
   part and single space characters MUST follow each of the TIMESTAMP
   and HOSTNAME fields.  HOSTNAME will contain the hostname, as it knows
   itself.  If it does not have a hostname, then it will contain its own
   IP address.  If a device has multiple IP addresses, it has usually
   been seen to use the IP address from which the message is
   transmitted.  An alternative to this behavior has also been seen.  In
   that case, a device may be configured to send all messages using a
   single source IP address regardless of the interface from which the
   message is sent.  This will provide a single consistent HOSTNAME for
   all messages sent from a device.

   The TIMESTAMP field is the local time and is in the format of "Mmm dd
   hh:mm:ss" (without the quote marks) where:

         Mmm is the English language abbreviation for the month of the
         year with the first character in uppercase and the other two
         characters in lowercase.  The following are the only acceptable
         values:

         Jan, Feb, Mar, Apr, May, Jun, Jul, Aug, Sep, Oct, Nov, Dec

         dd is the day of the month.  If the day of the month is less
         than 10, then it MUST be represented as a space and then the
         number.  For example, the 7th day of August would be
         represented as "Aug  7", with two spaces between the "g" and
         the "7".



Lonvick                      Informational                     [Page 10]


RFC 3164                The BSD syslog Protocol              August 2001


         hh:mm:ss is the local time.  The hour (hh) is represented in a
         24-hour format.  Valid entries are between 00 and 23,
         inclusive.  The minute (mm) and second (ss) entries are between
         00 and 59 inclusive.

   A single space character MUST follow the TIMESTAMP field.

   The HOSTNAME field will contain only the hostname, the IPv4 address,
   or the IPv6 address of the originator of the message.  The preferred
   value is the hostname.  If the hostname is used, the HOSTNAME field
   MUST contain the hostname of the device as specified in STD 13 [4].
   It should be noted that this MUST NOT contain any embedded spaces.
   The Domain Name MUST NOT be included in the HOSTNAME field.  If the
   IPv4 address is used, it MUST be shown as the dotted decimal notation
   as used in STD 13 [5].  If an IPv6 address is used, any valid
   representation used in RFC 2373 [6] MAY be used.  A single space
   character MUST also follow the HOSTNAME field.

4.1.3 MSG Part of a syslog Packet

   The MSG part will fill the remainder of the syslog packet.  This will
   usually contain some additional information of the process that
   generated the message, and then the text of the message.  There is no
   ending delimiter to this part.  The MSG part of the syslog packet
   MUST contain visible (printing) characters.  The code set
   traditionally and most often used has also been seven-bit ASCII in an
   eight-bit field like that used in the PRI and HEADER parts.  In this
   code set, the only allowable characters are the ABNF VCHAR values
   (%d33-126) and spaces (SP value %d32).  However, no indication of the
   code set used within the MSG is required, nor is it expected.  Other
   code sets MAY be used as long as the characters used in the MSG are
   exclusively visible characters and spaces similar to those described
   above.  The selection of a code set used in the MSG part SHOULD be
   made with thoughts of the intended receiver.  A message containing
   characters in a code set that cannot be viewed or understood by a
   recipient will yield no information of value to an operator or
   administrator looking at it.

   The MSG part has two fields known as the TAG field and the CONTENT
   field.  The value in the TAG field will be the name of the program or
   process that generated the message.  The CONTENT contains the details
   of the message.  This has traditionally been a freeform message that
   gives some detailed information of the event.  The TAG is a string of
   ABNF alphanumeric characters that MUST NOT exceed 32 characters.  Any
   non-alphanumeric character will terminate the TAG field and will be
   assumed to be the starting character of the CONTENT field.  Most
   commonly, the first character of the CONTENT field that signifies the




Lonvick                      Informational                     [Page 11]


RFC 3164                The BSD syslog Protocol              August 2001


   conclusion of the TAG field has been seen to be the left square
   bracket character ("["), a colon character (":"), or a space
   character.  This is explained in more detail in Section 5.3.

4.2 Original syslog Packets Generated by a Device

   There are no set requirements on the contents of the syslog packet as
   it is originally sent from a device.  It should be reiterated here
   that the payload of any IP packet destined to UDP port 514 MUST be
   considered to be a valid syslog message.  It is, however, RECOMMENDED
   that the syslog packet have all of the parts described in Section 4.1
   - PRI, HEADER and MSG - as this enhances readability by the recipient
   and eliminates the need for a relay to modify the message.

   For implementers that do choose to construct syslog messages with the
   RECOMMENDED format, the following guidance is offered.

         If the originally formed message has a TIMESTAMP in the HEADER
         part, then it SHOULD be the local time of the device within its
         timezone.

         If the originally formed message has a HOSTNAME field, then it
         will contain the hostname as it knows itself.  If it does not
         have a hostname, then it will contain its own IP address.

         If the originally formed message has a TAG value, then that
         will be the name of the program or process that generated the
         message.

4.3 Relayed syslog Packets

   When a relay receives a packet, it will check for a valid PRI.  If
   the first character is not a less-than sign, the relay MUST assume
   that the packet does not contain a valid PRI.  If the 3rd, 4th, or
   5th character is not a right angle bracket character, the relay again
   MUST assume that the PRI was not included in the original message.
   If the relay does find a valid PRI part then it must check for a
   valid TIMESTAMP in the HEADER part.  From these rules, there will be
   three general cases of received messages.  Table 3 gives the general
   characteristics of these cases and lists the subsequent section of
   this document that describes the handling of that case.

              Case                                         Section
         Valid PRI and TIMESTAMP                            4.3.1
         Valid PRI but no TIMESTAMP or invalid TIMESTAMP    4.3.2
         No PRI or unidentifiable PRI                       4.3.3

              Table 3. Cases of Received syslog Messages



Lonvick                      Informational                     [Page 12]


RFC 3164                The BSD syslog Protocol              August 2001


4.3.1 Valid PRI and TIMESTAMP

   If the relay does find a valid PRI and a valid TIMESTAMP, then it
   will check its internal configuration.  Relays MUST be configured to
   forward syslog packets on the basis of their Priority value.  If the
   relay finds that it is configured to forward the received packet,
   then it MUST do so without making any changes to the packet.  To
   emphasize the point one more time, it is for this reason that it is
   RECOMMENDED that the syslog message originally transmitted adhere to
   the format described in Section 4.1.

   It should be noted here that the message receiver does not need to
   validate the time in the TIMESTAMP field.  The assumption may be made
   that a device whose date has not been correctly set will still have
   the ability to send valid syslog messages.  Additionally, the relay
   does not need to validate that the value in the HOSTNAME field
   matches the hostname or IP address of the device sending the message.
   A reason for this behavior may be found in Section 4.1.2.

4.3.2 Valid PRI but no TIMESTAMP or invalid TIMESTAMP

   If a relay does not find a valid TIMESTAMP in a received syslog
   packet, then it MUST add a TIMESTAMP and a space character
   immediately after the closing angle bracket of the PRI part.  It
   SHOULD additionally add a HOSTNAME and a space character after the
   TIMESTAMP.  These fields are described here and detailed in Section
   4.1.2.  The remainder of the received packet MUST be treated as the
   CONTENT field of the MSG and appended.  Since the relay would have no
   way to determine the originating process from the device that
   originated the message, the TAG value cannot be determined and will
   not be included.

   The TIMESTAMP will be the current local time of the relay.

   The HOSTNAME will be the name of the device, as it is known by the
   relay.  If the name cannot be determined, the IP address of the
   device will be used.

   If the relay adds a TIMESTAMP, or a TIMESTAMP and HOSTNAME, after the
   PRI part, then it MUST check that the total length of the packet is
   still 1024 bytes or less.  If the packet has been expanded beyond
   1024 bytes, then the relay MUST truncate the packet to be 1024 bytes.
   This may cause the loss of vital information from the end of the
   original packet.  It is for this reason that it is RECOMMENDED that
   the PRI and HEADER parts of originally generated syslog packets
   contain the values and fields documented in Section 4.1.





Lonvick                      Informational                     [Page 13]


RFC 3164                The BSD syslog Protocol              August 2001


4.3.3 No PRI or Unidentifiable PRI

   If the relay receives a syslog message without a PRI, or with an
   unidentifiable PRI, then it MUST insert a PRI with a Priority value
   of 13 as well as a TIMESTAMP as described in Section 4.3.2.  The
   relay SHOULD also insert a HOSTNAME as described in Section 4.3.2.
   The entire contents of the received packet will be treated as the
   CONTENT of the relayed MSG and appended.

   An example of an unidentifiable PRI would be "<00>", without the
   double quotes.  It may be that these are the first 4 characters of
   the message.  To continue this example, if a relay does receive a
   syslog message with the first four characters of "<00>", then it will
   consult its configuration.  If it is configured to forward syslog
   messages with a Priority value of 13 to another relay or collector,
   then it MUST modify the packet as described above.  The specifics of
   doing this, including the RECOMMENDED insertion of the HOSTNAME, are
   given below.

   Originally received message
     <00>...
   Relayed message
     <13>TIMESTAMP HOSTNAME <00>...

   If the relay adds a TIMESTAMP, or a TIMESTAMP and HOSTNAME, after the
   PRI part, then it MUST check that the total length of the packet is
   still 1024 bytes or less.  If the packet has been expanded beyond
   1024 bytes, then the relay MUST truncate the packet to be 1024 bytes.
   This may cause the loss of vital information from the end of the
   original packet.  It is for this reason that it is RECOMMENDED that
   the PRI and HEADER parts of originally generated syslog packets
   contain the values and fields documented in Section 4.1.

5. Conventions

   Although Section 4 of this document specifies all requirements for
   the syslog protocol format and contents, certain conventions have
   come about over time for the inclusion of additional information
   within the syslog message.  It must be plainly stated that these
   items are not mandated but may be considered by implementers for
   completeness and to give the recipient some additional clues of their
   origin and nature.









Lonvick                      Informational                     [Page 14]


RFC 3164                The BSD syslog Protocol              August 2001


5.1 Dates and Times

   It has been found that some network administrators like to archive
   their syslog messages over long periods of time.  It has been seen
   that some original syslog messages contain a more explicit time stamp
   in which a 2 character or 4 character year field immediately follows
   the space terminating the TIMESTAMP.  This is not consistent with the
   original intent of the order and format of the fields.  If
   implementers wish to contain a more specific date and time stamp
   within the transmitted message, it should be within the CONTENT
   field.  Implementers may wish to utilize the ISO 8601 [7] date and
   time formats if they want to include more explicit date and time
   information.

   Additional methods to address this desire for long-term archiving
   have been proposed and some have been successfully implemented.  One
   such method is that the network administrators may choose to modify
   the messages stored on their collectors.  They may run a simple
   script to add the year, and any other information, to each stored
   record.  Alternatively, the script may replace the stored time with a
   format more appropriate for the needs of the network administrators.
   Another alternative has been to insert a record into the file that
   contains the current year.  By association then, all other records
   near that informative record should have been received in that same
   year.  Neither of these however, addresses the issue of associating a
   correct timezone with each record.

5.2 Domain Name and Address

   To readily identify the device that originated the message, it may be
   a good practice to include its fully qualified domain name (FQDN) and
   its IP address within the CONTENT field.  Traditionally, however,
   only the hostname has been included in the HOSTNAME field.

5.3 Originating Process Information

   It has also been considered to be a good practice to include some
   information about the process on the device that generated the
   message - if that concept exists.  This is usually the process name
   and process id (often known as the "pid") for robust operating
   systems.  The process name is commonly displayed in the TAG field.
   Quite often, additional information is included at the beginning of
   the CONTENT field.  The format of "TAG[pid]:" - without the quote
   marks - is common.  The left square bracket is used to terminate the
   TAG field in this case and is then the first character in the CONTENT
   field.  If the process id is immaterial, it may be left off.





Lonvick                      Informational                     [Page 15]


RFC 3164                The BSD syslog Protocol              August 2001


   In that case, a colon and a space character usually follow the TAG.
   This would be displayed as "TAG: " without the quotes.  In that case,
   the colon is the first character in the CONTENT field.

5.4 Examples

   As examples, these are valid messages as they may be observed on the
   wire between two devices.  In the following examples, each message
   has been indented, with line breaks inserted in this document for
   readability.

        Example 1

        <34>Oct 11 22:14:15 mymachine su: 'su root' failed for lonvick
        on /dev/pts/8

   This example shows an authentication error in an attempt to acquire
   additional privileges.  It also shows the command attempted and the
   user attempting it.  This was recorded as an original message from
   the device called mymachine.  A relay receiving this would not make
   any changes before sending it along as it contains a properly
   formatted PRI part and TIMESTAMP field in the HEADER part.  The TAG
   value in this example is the process "su".  The colon has terminated
   the TAG field and is the first character of the CONTENT field.  In
   this case, the process id (pid) would be considered transient and
   anyone looking at this syslog message would gain no useful
   information from knowing the pid.  It has not been included so the
   first two characters of the CONTENT field are the colon and a space
   character.

        Example 2

        Use the BFG!

   While this is a valid message, it has extraordinarily little useful
   information.  This message does not have any discernable PRI part. It
   does not contain a timestamp or any indication of the source of the
   message.  If this message is stored on paper or disk, subsequent
   review of the message will not yield anything of value.

   This example is obviously an original message from a device.  A relay
   MUST make changes to the message as described in Section 4.3 before
   forwarding it.  The resulting relayed message is shown below.

        <13>Feb  5 17:32:18 10.0.0.99 Use the BFG!






Lonvick                      Informational                     [Page 16]


RFC 3164                The BSD syslog Protocol              August 2001


   In this relayed message, the entire message has been treated as the
   CONTENT portion of the MSG part.  First, a valid PRI part has been
   added using the default priority value of 13.  Next, a TIMESTAMP has
   been added along with a HOSTNAME in the HEADER part.  Subsequent
   relays will not make any further changes to this message.  It should
   be noted in this example that the day of the month is less than 10.
   Since single digits in the date (5 in this case) are preceded by a
   space in the TIMESTAMP format, there are two spaces following the
   month in the TIMESTAMP before the day of the month.  Also, the relay
   appears to have no knowledge of the host name of the device sending
   the message so it has inserted the IPv4 address of the device into
   the HOSTNAME field.

        Example 3

         <165>Aug 24 05:34:00 CST 1987 mymachine myproc[10]: %% It's
         time to make the do-nuts.  %%  Ingredients: Mix=OK, Jelly=OK #
         Devices: Mixer=OK, Jelly_Injector=OK, Frier=OK # Transport:
         Conveyer1=OK, Conveyer2=OK # %%

   This message does have a valid PRI part with a Priority value
   indicating that it came from a locally defined facility (local4) with
   a severity of Notice.  The HEADER part has a proper TIMESTAMP field
   in the message.  A relay will not modify this message before sending
   it.  However, the HOSTNAME and TAG fields are not consistent with the
   definitions in Section 4.  The HOSTNAME field would be construed to
   be "CST" and the beginning of the MSG part would be "1987".

   It should be noted that the information contained in the CONTENT of
   this example is not telemetry data, nor is it supervisory control or
   data acquisition information.  Due to the security concerns listed in
   Section 6 of this document, information of that nature should
   probably not be conveyed across this protocol.

        Example 4

         <0>1990 Oct 22 10:52:01 TZ-6 scapegoat.dmz.example.org 10.1.2.3
         sched[0]: That's All Folks!

   This example has a lot of extraneous information throughout.  A human
   or sufficiently adaptable automated parser would be able to determine
   the date and time information as well as a fully qualified domain
   name (FQDN) [4] and IP address.  The information about the nature of
   the event is, however, limited.  Due to the indicated severity of the
   event, the process may not have been able to gather or send anything
   more informative.  It may have been fortunate to have generated and
   sent this message at all.




Lonvick                      Informational                     [Page 17]


RFC 3164                The BSD syslog Protocol              August 2001


   This example is obviously an original message from a device.  Since
   the first field in the HEADER part is not a TIMESTAMP in the format
   defined in Section 4.1.2, it MUST be modified by a relay.  A relay
   will add a TIMESTAMP and SHOULD add a HOSTNAME as follows and will
   treat the entire received packet after the PRI part from the original
   packet as the CONTENT field of the new packet.  The value used in the
   HOSTNAME field is only the hostname without the domain name as it is
   known by the relay.  A TAG value will not be added to the relayed
   packet.  While the inclusion of the domain name and IPv4 address in
   the original message is a noble endeavor, it is not consistent with
   the use of the field as described in Section 4.1.2.

         <0>Oct 22 10:52:12 scapegoat 1990 Oct 22 10:52:01 TZ-6
         scapegoat.dmz.example.org 10.1.2.3 sched[0]: That's All Folks!

6. Security Considerations

   An odor may be considered to be a message that does not require any
   acknowledgement.  People tend to avoid bad odors but are drawn to
   odors that they associate with good food.  The acknowledgement of the
   receipt of the odor or scent is not required and indeed it may be the
   height of discretion to totally ignore some odors.  On the other
   hand, it is usually considered good civility to acknowledge the
   prowess of the cook merely from the ambiance wafting from the
   kitchen.  Similarly, various species have been found to utilize odors
   to attract mates.  One species of moth uses this scent to find each
   other.  However, it has been found that bolas spiders can mimic the
   odor of the female moths of this species.  This scent will then
   attract male moths, which will follow it with the expectation of
   finding a mate.  Instead, when they arrive at the source of the
   scent, they will be eaten [8].  This is a case of a false message
   being sent out with inimical intent.

   In its local use, the syslog process places event notification
   messages into files on that system.  This relies upon the integrity
   of the system for the protection of the messages.  The subsequent
   configuration of the syslog process to use the syslog protocol to
   transport the messages to a remote collector was an extension of the
   delivery of event notification messages and it exhibits the same
   trust of the network.  There are several security consequences of the
   fundamental simplicity of syslog and there are some concerns about
   the applicability of this protocol in situations that require robust
   delivery.  Along the lines of the analogy, computer event messages
   may be sent accidentally, erroneously and even maliciously. At the
   time of this writing, however, there have not been any reports of any
   networked device consuming any other device.





Lonvick                      Informational                     [Page 18]


RFC 3164                The BSD syslog Protocol              August 2001


6.1 Packet Parameters

   As was described above, the message length MUST NOT exceed 1024
   bytes.  Attacks have seen where syslog messages are sent to a
   receiver that have message lengths greater than 1024 bytes.  In some
   older versions of syslog, the receipt of syslog packets that had a
   message greater than 1024 bytes caused problems.  syslog message
   receivers must not malfunction upon the receipt of packets where the
   message length is greater than 1024 bytes.  Various behaviors have
   been seen on receivers that do receive messages greater than 1024
   bytes.  Some have been seen to log the entire contents of the
   message, while others have been seen to log only portions of the
   message.  Still others have been known to discard the message
   altogether.  Devices MUST NOT retransmit messages whose received
   length exceeds 1024 bytes.

   Similarly, the receiver must rigidly enforce the correctness of the
   message body.  syslog collectors must not malfunction if received
   messages do not have the less-than and greater-than characters around
   a valid Priority value.  They MUST treat these messages as the
   unformatted CONTENT as was described in