Printer Friendly

GPC/SEC with triple detection.

Recent work published by experts from Viscotek, a Malvern company, showcases the TDAmax gel permeation/size exclusion chromatography (GPC/SEC) system as an information-rich, time-efficient analytical solution for the comprehensive characterization of complex food ingredients and additives based on polysaccharides.

The Viscotek TDAmax sets the benchmark for GPC/SEC, with a fully integrated triple detector array that includes a revolutionary low angle light scattering detector (LALS), four capillary differential viscometer and refractive index detector.

Using GPC/SEC, passing a sample through a series of carefully specified packed columns separates it on the basis of hydrodynamic size. Single or multiple detectors analyze the resulting fractions. The design and selection of the detectors dictates how much information can be gathered during each experiment. The TDAmax detector array provides absolute molecular weight without extrapolation or correction, molecular size, and intrinsic viscosity, as well as information on structure, conformation, aggregation and branching. Adding an additional UV/Vis detector, creates an integrated tetra detector array ideal for copolymer characterization.

The performance characteristics of a range of food ingredients depend on their molecular weight and structure. It is also possible that low molecular weight fractions in some ingredients may even be harmful to human health. It is important therefore to confirm that these have been removed. Many food ingredients have large molecular sizes, however, and this can present a challenge in accurately determining molecular weight distribution. The research detailed in the paper shows that the TDAmax can meet this analytical challenge and that it provides accurate and detailed information.

[ILLUSTRATION OMITTED]

Contact Malvern on 01684 892456 or visit www.malvern.com & www.viscotek.com
COPYRIGHT 2009 Food Trade Press Ltd.
No portion of this article can be reproduced without the express written permission from the copyright holder.
Copyright 2009 Gale, Cengage Learning. All rights reserved.

Article Details
Printer friendly Cite/link Email Feedback
Title Annotation:PLANT AND EQUIPMENT
Publication:Food Trade Review
Date:Oct 1, 2009
Words:268
Previous Article:Refrigerant air dryers minimum energy profiles.
Next Article:Ansell new customer experience platform.
Topics:


Related Articles
Chromatography tester. (Instruments).
Polymer characterization.
Polymer characterization.
Triple detector array.
Multiple detection.
Triple detector.
Triple detection polymer testing.
Series of technical articles describes triple detection GPC/SEC testing.
New Viscotek GPC/SEC detector.

Terms of use | Privacy policy | Copyright © 2025 Farlex, Inc. | Feedback | For webmasters |